Frankonia

Home > 제품소개 > Frankonia

제목 Frankonia 사의 종합 카탈로그입니다. 등록일 2018.07.25 18:13
글쓴이 YM tech 조회 999



안녕하세요.
프랑코니아사의 종합 카탈로그입니다.
https://blog.naver.com/twoyoung_office/221326399313 여기에서 선명한 이미지 파일을 얻으실 수 있습니다.
문의사항 있으신 분은 연락 주시기 바랍니다.
감사합니다.


EMC 종합 카탈로그-Frankonia page1.jpg

EMC 종합 카탈로그-Frankonia page2.jpg


Frankonia - Emission Measurements
EMI-Receiver Core-6
- Input: 9kHz - 30MHz/30MHz - 6GHz
- Resolution: 0.1 Hz/100Hz
- RF input: 50Ω BNC/50Ω N


EMI-Receiver ERX-6 (Full-Compliance)
- according to CISPR 16-1-1 Ed 3.1 and MIL461G
- FFT-based measuring instrument
- 0 dB attenuator: VSWR<2.0 (9kHz - 1GHz)
- 10 dB attenuator: VSWR<3.0(1GHz - 6GHz)
ALX-8000E
Broad band Antenna 30MHz-7GHz
ALX-4000/ALX-4000E
Broadband antenna for emission measurements & immunity tests
- 25MHz - 4GHz
MAX-9
Stacked logarithmic - periodic broadband antenna
- 600MHz - 10.5GHz
MAX-18
Microwave Log.-Per. antenna
- 1GHz - 18GHz
HAX-6
- Low SWR
- 500MHz - 6GHz
HAX-18
- Low SWR
- 800MHz - 18GHz
HAX-40
- Low SWR
- 14GHz - 40GHz
Active monopole SAX-10
- Built-in  rechargeable batteries
- 9kHz - 30MHz
Active loop antenna LAX-40
- combined with a CISPR-16
- 9kHz - 30MHz
FPA-2 / FPA-6A / FPA-6B
- broadband pre-amplifier with high gain and low internal noise
- 9kHz~2GHz/10MHz~6GHz/9kHz~6GHz
FPA-18
- Low noise low power wideband amplifier
- 1GHz~18GHz
FPA-26
- Low noise low power wideband amplifier
- 18GHz~26.5GHz
FPA-40
- Low noise low power wideband amplifier
- 18GHz~40GHz
 Electrical Polarization Switch FPD-01

- Polarization electric: 0° ~ 90°
- Polarization accuracy: 0.2°
Manual Antenna Masts 
FSM-1.6, FSM-2.0 and FSM 4.0
- Height range: 0.9~1.6m/1.2~2.0m/0.4~4.15m
- Mast Material: fibre glass
- Maximum antenna weight: 5kg
Frankonia Antenna Mast FAM2-4, FAM2-6
- Polarization: Electric, 0° to 90°
- Polarization time: approx. 6 sec
- Polarization accuracy: 0.2°
- Height scan(Electric): 0.9~4.0m/0.9~6.0m
- Height scan accuracy: ±5mm

Frankonia Boresight Antenna Mast FBM
- Polarization: Electric, 0° to 90°
- Polarization time: approx. 6 sec
- Polarization accuracy: 0.2°
- Height scan(Electric): 0.9~4.0m
- Height scan accuracy: ±5mm

Compact Immunity Test System CIT-10
- Signal generator, RF power amplifier, RF power meter 
  and directional coupler in one case
- Frequency range: 10kHz to 400MHz
- Frequency resolution: 1Hz
- RF power amplifier: 25W/75W
- Amplitude modulation: 0 to 100%, resolution 0.5%
new CIT-1000
- Conducted RF immunity test acc. to IEC/EN 61000-4-6, BCI
  tests acc. to ISO 11452-4 and MIL-STD 461
- Signal-generator and RF power meter can be used for acc.
   to IEC/EN 61000-4-3 
- Frequency range: 9kHz to 1.2GHz
- Frequency resolution: 1Hz
- RF power amplifier: 25W/75W/180W
- Low Frequency extension: 4kHz, 250W (option)

Coupling/Decoupling Networks CDNs
- For immunity testing acc. To IEC 61000-4-6
- Type: M, AF, S, T, Rj, USB, etc.
Coupling Clamp EMCL-25, EMCL-35
- Frequency range: 10kHz~1GHz
- Nominal impedance: 50Ω
Bulk current injection BCI Probe
- ISO 11452-4 and IEC 61000-4-6
- Frequency range: 4kHz up to 400MHz
Bulk current monitoring MP-50
- ISO 11452-4 and IEC 61000-4-6
- Frequency range: 4kHz up to 400MHz
Differential mode disturbances PSG-300, PGS-300A
- Immunity testing acc. To IEC/EN 61000-4-16, 
  IEC/EN 61000-4-19 and IEC/EN 61543
- Power bandwidth: DC ~ 200kHz
- Slew rate: 100 V/㎲
- Output voltage 50Veff/±75Vpeak
- Output current: 5Aeff(16Aeff)/±7.5Apeak(±23Apeak)
- Power output: 250W(800W)
Universal Coupling Network M2345/32-16
- Switchable coupling network acc. To IEC 61000-4-16
- Current rating up to 125A
- For continuous and short term tests up to ±300V
- Remote control in connection with MTS-800, PSG-300
- EUT 250V AC or DC
Magnetic field/Low frequency Test System MTS-800
- Acc. to IEC 55103-1/2, IEC 61000-4-16, IEC 61000-4-8, SAE
  J1113-22, ISO 11452-8, MIL-STD-461(CE101, RE101, CS101,
  CS109 and RS101), automotive manufacturer standards
- Frequency range for emission and immunity: DC ~ 250kHz
- 800W precision power amplifier, signal generator and
  spectrum analyzer in one compact unit
Conducted Immunity Amplifiers
* Frequency range
- 10kHz~300 MHz: FLL, VLL series up to 12000W
- 10kHz~400 MHz: VLC, FLC series up to 2000W
- 10 kHz ~ 1000MHz: VLLH series up to 800W
- 1 MHz ~ 1000 MHz: FLH series up to 200W 
RF Power meter  PMS 1084, PMS 1084B
- Number of channels: 2 up to 4
- Frequency range LF: 10 kHz ~ 500 MHz
- Frequency range HF: 100 kHz ~ 6 GHz
- Resolution: 0.1dB
Relay Switching Unit RSU
- Frequency range: DC to 12.4 GHz (40 GHz optional)
- Test level: 50V cont., 300 V 1s
- Number of operations: Max. 10/Minute
Field Stregth Meter EFS-10/100/300/50
- Extreme small size, Excellent isotropy
- Frequency range: 10kHz to 26.5GHz
- Up to 80 hours operating time
EMC Control Unit ECU-3, ECU-6
- Conducted immunity, IEC/EN 61000-4-6, 10kHz~230MHz
- BCI-tests, ISO 11452-4 and MIL_STD 461, CS 114
- Radiated Immunity, IEC/EN 61000-4-3, ISO 11452-2/3/4/5, 
  MIL-STD 461, RS 103
- Automatic switching between up to two EMI-receivers,
  spectrum analyzers and three different antennas
- Frequency range: 9kHz to 3GHz, 9kHz to 6.5GHz
Field Strength Meter EFS-Laser
- Laser powered, High resolution,
  high speed, low noise
- 10kHz to 6GHz, up to 10kV/m
Antennas AXL-80 /80ES/200
- Radiated immunity, Emission measurements acc. To automotive standards
- 70MHz ~ 4GHz, 80MHz~2.7GHz,
  150MHz ~ 4GHz
Amplifiers
- 20MHz ~ 1GHz, FLH, VLH series
- 80MHz ~ 1GHz, FLH, VLH series
- 0.8GHz ~ 2GHz, FLG series
- 0.8GHz ~ 3.2GHz, FLG, VLG series
- 0.8GHz ~ 4GHz, VLG series
- 2GHz ~ 4GHz, FLG series
- 2GHz ~ 6GHz, FLG, VLG series
- 0.7GHz ~ 6GHz, FLG series
- 0.8GHz ~ 6GHz  VLG series
Commercial Chambers
Automotive Chambers
Military Chambers
Mobile Load Machine - BlueBox
- Compliance: CISPR 25 Ed.4
- Features: Plug&Play system, Useable for motor, 
   components or combination with battery tests
- Volume: Table setup, connection to a CISPR 25 table
- Integration kit for existing chambers